{"id":13194,"date":"2026-05-19T07:04:19","date_gmt":"2026-05-19T07:04:19","guid":{"rendered":"https:\/\/www.kalitekit.com.tr\/soru-cevap\/mdcg-2023-7-yeni-cihazlarda-klinik-arastirma-istisnasini-nasil-etkiler\/"},"modified":"2026-09-22T14:24:50","modified_gmt":"2026-09-22T11:24:50","slug":"mdcg-2023-7-yeni-cihazlarda-klinik-arastirma-istisnasini-nasil-etkiler","status":"publish","type":"kkqa_question","link":"http:\/\/www.kalitekit.com.tr\/en\/soru-cevap\/mdcg-2023-7-yeni-cihazlarda-klinik-arastirma-istisnasini-nasil-etkiler\/","title":{"rendered":"MDCG 2023-7 yeni cihazlarda klinik ara\u015ft\u0131rma istisnas\u0131n\u0131 nas\u0131l etkiler?"},"content":{"rendered":"<p>Klinik de\u011ferlendirme yaln\u0131zca literat\u00fcr listesi de\u011fildir; cihaz\u0131n ama\u00e7lanan kullan\u0131m\u0131n\u0131, klinik iddialar\u0131n\u0131, risklerini ve performans kan\u0131tlar\u0131n\u0131 bir araya getiren s\u00fcrekli bir s\u00fcre\u00e7tir. Yeni cihazlarda klinik ara\u015ft\u0131rma istisnas\u0131 dar yorumlan\u0131r; e\u015fde\u011ferlik, mevcut veri ve risk s\u0131n\u0131f\u0131 gerek\u00e7eleri ayr\u0131nt\u0131l\u0131 olmal\u0131d\u0131r. \u00dcretici, kullan\u0131lan verinin kalitesini, veri kayna\u011f\u0131na eri\u015fimi, e\u015fde\u011ferlik gerek\u00e7esini ve PMS\/PMCF \u00e7\u0131kt\u0131lar\u0131n\u0131n CER \u00fczerindeki etkisini a\u00e7\u0131k\u00e7a yazmal\u0131d\u0131r. Sonu\u00e7 b\u00f6l\u00fcm\u00fcnde klinik fayda-risk kabul\u00fc \u00fcr\u00fcn \u00f6zelinde gerek\u00e7elendirilmelidir.<\/p>\n\n\n<p class=\"wp-block-paragraph\">MDCG 2023-7, MDR Madde 61(4)-(6) kapsam\u0131nda implant edilebilir ve S\u0131n\u0131f III cihazlar i\u00e7in klinik ara\u015ft\u0131rma yap\u0131lmas\u0131 zorunlulu\u011funun hangi durumlarda uygulanmayabilece\u011fini a\u00e7\u0131klayan rehberdir. Rehber, klinik ara\u015ft\u0131rmadan genel bir muafiyet sa\u011flamaz. \u00dcreticinin ilgili istisna \u015fartlar\u0131n\u0131n tamam\u0131n\u0131 cihaz \u00f6zelinde kan\u0131tlamas\u0131 gerekir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">MDR Madde 61(4) uyar\u0131nca implant edilebilir ve S\u0131n\u0131f III cihazlarda temel yakla\u015f\u0131m klinik ara\u015ft\u0131rma ger\u00e7ekle\u015ftirilmesidir. Klinik ara\u015ft\u0131rma yap\u0131lmamas\u0131 ancak MDR\u2019de tan\u0131mlanan istisna yollar\u0131ndan birinin uygulanabilir olmas\u0131 ve mevcut klinik kan\u0131tlar\u0131n cihaz\u0131n g\u00fcvenlili\u011fini, performans\u0131n\u0131 ve klinik faydas\u0131n\u0131 g\u00f6stermek i\u00e7in yeterli bulunmas\u0131 h\u00e2linde m\u00fcmk\u00fcnd\u00fcr.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">MDCG 2023-7 kapsam\u0131nda \u201cyeni cihaz\u201d ifadesi yaln\u0131zca teknik olarak yenilik\u00e7i veya piyasada benzeri bulunmayan \u00fcr\u00fcnleri anlatmaz. Rehberdeki birinci ve d\u00f6rd\u00fcnc\u00fc istisna senaryolar\u0131nda de\u011ferlendirilen cihazlar, daha \u00f6nce MDD, AIMDD veya MDR kapsam\u0131nda piyasaya arz edilmemi\u015f cihazlar olarak ele al\u0131n\u0131r. Bununla birlikte yeni cihaz\u0131n, ayn\u0131 \u00fcreticinin mevcut cihaz\u0131n\u0131n de\u011fi\u015ftirilmi\u015f bir tasar\u0131m\u0131 olmas\u0131 veya ba\u015fka bir \u00fcreticinin piyasadaki cihaz\u0131na e\u015fde\u011ferli\u011finin g\u00f6sterilmesi m\u00fcmk\u00fcn olabilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Birinci istisna senaryosu, yeni cihaz\u0131n ayn\u0131 \u00fcretici taraf\u0131ndan daha \u00f6nce piyasaya arz edilmi\u015f bir cihaz\u0131n tasar\u0131m de\u011fi\u015fikli\u011fiyle geli\u015ftirilmi\u015f olmas\u0131d\u0131r. Bu yolun uygulanabilmesi i\u00e7in de\u011ferlendirilen cihaz ile \u00fcreticinin mevcut cihaz\u0131 aras\u0131nda MDR Ek XIV B\u00f6l\u00fcm A K\u0131s\u0131m 3\u2019e uygun e\u015fde\u011ferlik kurulmal\u0131d\u0131r. E\u015fde\u011ferlik de\u011ferlendirmesi onaylanm\u0131\u015f kurulu\u015f taraf\u0131ndan kabul edilmeli ve mevcut cihaz\u0131n klinik de\u011ferlendirmesi, de\u011fi\u015ftirilmi\u015f yeni cihaz\u0131n ilgili genel g\u00fcvenlilik ve performans gerekliliklerine uygunlu\u011funu g\u00f6sterecek kadar yeterli olmal\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ayn\u0131 \u00fcreticinin mevcut cihaz\u0131na dayan\u0131lmas\u0131, yeni cihaz i\u00e7in ayr\u0131 bir klinik de\u011ferlendirme raporu haz\u0131rlanmas\u0131 gereklili\u011fini ortadan kald\u0131rmaz. Yeni cihaz\u0131n kullan\u0131m amac\u0131, tasar\u0131m\u0131, teknik \u00f6zellikleri, malzemeleri, temas \u015fekli, klinik performans\u0131 ve risk profili mevcut cihazla kar\u015f\u0131la\u015ft\u0131r\u0131lmal\u0131d\u0131r. Tespit edilen her farkl\u0131l\u0131\u011f\u0131n e\u015fde\u011ferlik ve klinik kan\u0131t \u00fczerindeki etkisi gerek\u00e7elendirilmelidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Birinci istisna yolu kullan\u0131ld\u0131\u011f\u0131nda PMCF plan\u0131, piyasaya sunulan yeni cihaz\u0131n kendi g\u00fcvenlilik ve performans verilerinin toplanmas\u0131n\u0131 sa\u011flayacak piyasa sonras\u0131 klinik takip \u00e7al\u0131\u015fmalar\u0131n\u0131 i\u00e7ermelidir. \u00dcretici, yaln\u0131zca mevcut veya e\u015fde\u011fer cihaz\u0131n verilerine s\u00fcresiz bi\u00e7imde dayanamaz. Yeni cihazdan elde edilen klinik veriler, sonraki klinik de\u011ferlendirme g\u00fcncellemelerine d\u00e2hil edilmelidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0130kinci istisna senaryosu, cihaz\u0131n MDD veya AIMDD kapsam\u0131nda yasal olarak piyasaya arz edilmi\u015f veya hizmete sunulmu\u015f olmas\u0131d\u0131r. Bu legacy cihazlarda klinik ara\u015ft\u0131rma yap\u0131lmamas\u0131 i\u00e7in klinik de\u011ferlendirmenin yeterli klinik verilere dayanmas\u0131 gerekir. \u0130lgili cihaz t\u00fcr\u00fc i\u00e7in \u00fcr\u00fcn \u00f6zelinde ortak spesifikasyon bulunuyorsa klinik de\u011ferlendirmenin bu spesifikasyona da uygun olmas\u0131 beklenir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bir cihaz\u0131n ge\u00e7mi\u015fte MDD veya AIMDD kapsam\u0131nda CE belgeli olmas\u0131 tek ba\u015f\u0131na klinik ara\u015ft\u0131rma istisnas\u0131 i\u00e7in yeterli de\u011fildir. \u00dcretici; mevcut klinik verilerin g\u00fcncel kullan\u0131m amac\u0131, hedef hasta grubu, endikasyonlar, riskler ve performans iddialar\u0131 bak\u0131m\u0131ndan MDR gerekliliklerini destekledi\u011fini g\u00f6stermelidir. Eski sertifika, klinik kan\u0131t eksikliklerini otomatik olarak ortadan kald\u0131rmaz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00dc\u00e7\u00fcnc\u00fc istisna senaryosu MDR Madde 61(6)(b)\u2019de belirtilen yerle\u015fik teknolojili cihaz gruplar\u0131d\u0131r. S\u00fct\u00fcrler, staplerler, dental dolgular, di\u015f telleri, di\u015f kronlar\u0131, vidalar, kamalar, plakalar, teller, pinler, klipsler ve konekt\u00f6rler bu kapsamda de\u011ferlendirilir. Bu cihazlarda da klinik ara\u015ft\u0131rman\u0131n zorunlu olmamas\u0131 i\u00e7in yeterli klinik veri bulunmal\u0131 ve varsa ilgili \u00fcr\u00fcn \u00f6zelindeki ortak spesifikasyon kar\u015f\u0131lanmal\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00dcr\u00fcn\u00fcn listedeki cihazlardan biriyle ayn\u0131 ticari isme sahip olmas\u0131 tek ba\u015f\u0131na yerle\u015fik teknoloji istisnas\u0131n\u0131 kullanmak i\u00e7in yeterli de\u011fildir. Kullan\u0131m amac\u0131, tasar\u0131m \u00f6zellikleri, malzeme, anatomik b\u00f6lge, kullan\u0131m s\u00fcresi, invazivlik, hedef pop\u00fclasyon ve riskler de\u011ferlendirilmelidir. Yenilik\u00e7i malzeme, farkl\u0131 etki mekanizmas\u0131 veya yeni klinik iddialar mevcut kan\u0131tlar\u0131n yeterlili\u011fini de\u011fi\u015ftirebilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u00f6rd\u00fcnc\u00fc istisna senaryosu, yeni cihaz\u0131n ba\u015fka bir \u00fcretici taraf\u0131ndan piyasaya arz edilmi\u015f bir cihaza e\u015fde\u011fer oldu\u011funun g\u00f6sterilmesine dayan\u0131r. Bu durumda iki \u00fcretici aras\u0131nda, yeni cihaz \u00fcreticisine e\u015fde\u011fer cihaz\u0131n teknik dok\u00fcmantasyonuna s\u00fcrekli ve tam eri\u015fim sa\u011flayan a\u00e7\u0131k bir s\u00f6zle\u015fme bulunmal\u0131d\u0131r. E\u015fde\u011fer cihaz\u0131n klinik de\u011ferlendirmesinin MDR\u2019ye uygun yap\u0131lm\u0131\u015f oldu\u011fu da onaylanm\u0131\u015f kurulu\u015fa kan\u0131tlanmal\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ba\u015fka bir \u00fcreticinin cihaz\u0131na dayan\u0131lan d\u00f6rd\u00fcnc\u00fc senaryoda yaln\u0131zca kamuya a\u00e7\u0131k literat\u00fcr, kullan\u0131m k\u0131lavuzu, patent, internet sitesi veya pazarlama materyalleri \u00e7o\u011funlukla tam teknik dok\u00fcmantasyon eri\u015fiminin yerine ge\u00e7mez. S\u00f6zle\u015fmede eri\u015filecek belgelerin kapsam\u0131, eri\u015fimin s\u00fcreklili\u011fi, g\u00fcncellemelerin payla\u015f\u0131lmas\u0131, gizlilik, de\u011fi\u015fikliklerin bildirilmesi ve s\u00f6zle\u015fmenin sona ermesi durumunda klinik kan\u0131t\u0131n nas\u0131l korunaca\u011f\u0131 tan\u0131mlanmal\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">MDCG 2023-7, d\u00f6rt istisna senaryosunun birbirinden ba\u011f\u0131ms\u0131z oldu\u011funu a\u00e7\u0131klar. Ba\u015fka \u00fcreticinin cihaz\u0131na dayanan Madde 61(5) senaryosu d\u0131\u015f\u0131nda her durumda iki \u00fcretici aras\u0131nda s\u00f6zle\u015fme bulunmas\u0131 zorunlu de\u011fildir. Ancak s\u00f6zle\u015fme gerekmeyen durumlarda da \u00fcretici, e\u015fde\u011ferli\u011fi kurmak i\u00e7in ihtiya\u00e7 duydu\u011fu klinik, teknik ve biyolojik verilere yeterli d\u00fczeyde eri\u015fti\u011fini g\u00f6stermelidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u201cYeterli veri eri\u015fimi\u201d, e\u015fde\u011fer cihaz\u0131n b\u00fct\u00fcn teknik dosyas\u0131n\u0131n mutlaka elde edilmesi anlam\u0131na gelmez. \u00dcreticinin, MDR Ek XIV\u2019teki klinik, teknik ve biyolojik e\u015fde\u011ferlik \u00f6zelliklerini eksiksiz ve g\u00fcvenilir \u015fekilde kar\u015f\u0131la\u015ft\u0131rmas\u0131na imk\u00e2n verecek verilere sahip olmas\u0131 gerekir. Hangi verilere nas\u0131l eri\u015fildi\u011fi ve bu eri\u015fim seviyesinin neden yeterli oldu\u011fu klinik de\u011ferlendirme raporunda gerek\u00e7elendirilmelidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Teknik e\u015fde\u011ferlik de\u011ferlendirmesinde tasar\u0131m, kullan\u0131m ko\u015fullar\u0131, \u00e7al\u0131\u015fma prensibi, kritik performans \u00f6zellikleri, teknik \u00f6zellikler ve uygulama y\u00f6ntemi kar\u015f\u0131la\u015ft\u0131r\u0131lmal\u0131d\u0131r. Biyolojik e\u015fde\u011ferlikte hasta veya kullan\u0131c\u0131yla temas eden malzemeler, temas t\u00fcr\u00fc ve s\u00fcresi, maddelerin sal\u0131nmas\u0131 ve biyolojik g\u00fcvenlilik dikkate al\u0131nmal\u0131d\u0131r. Klinik e\u015fde\u011ferlikte ise kullan\u0131m amac\u0131, hedef pop\u00fclasyon, anatomik b\u00f6lge, kullan\u0131c\u0131 grubu, hastal\u0131k \u015fiddeti, klinik performans ve beklenen klinik sonu\u00e7lar kar\u015f\u0131la\u015ft\u0131r\u0131lmal\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">E\u015fde\u011ferlik de\u011ferlendirmesi yaln\u0131zca benzerliklerin s\u0131raland\u0131\u011f\u0131 bir tablo olarak haz\u0131rlanmamal\u0131d\u0131r. Cihazlar aras\u0131ndaki farkl\u0131l\u0131klar\u0131n g\u00fcvenlilik, klinik performans ve klinik fayda \u00fczerindeki etkisi a\u00e7\u0131klanmal\u0131d\u0131r. Bir farkl\u0131l\u0131k klinik sonu\u00e7lar\u0131 etkileyebilecek nitelikteyse e\u015fde\u011ferlik iddias\u0131 zay\u0131flayabilir veya ge\u00e7ersiz h\u00e2le gelebilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Veri eri\u015fim seviyesinin y\u00fcksek olmas\u0131 tek ba\u015f\u0131na e\u015fde\u011ferli\u011fin ba\u015far\u0131yla g\u00f6sterildi\u011fi anlam\u0131na gelmez. \u00dcretici e\u015fde\u011fer cihaz\u0131n teknik dok\u00fcmantasyonuna tam eri\u015fse bile, cihazlar\u0131n klinik, teknik veya biyolojik \u00f6zellikleri aras\u0131nda \u00f6nemli farkl\u0131l\u0131klar bulunabilir. Buna kar\u015f\u0131l\u0131k ayn\u0131 tasar\u0131m \u00f6zelliklerine sahip cihazlar\u0131n ortak bir \u00fcretici taraf\u0131ndan farkl\u0131 yasal \u00fcreticilere sunuldu\u011fu baz\u0131 durumlarda, gerekli teknik ve biyolojik verilere eri\u015fim daha g\u00fc\u00e7l\u00fc olabilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00dcretici, e\u015fde\u011ferli\u011fi g\u00f6stermek i\u00e7in gerekli verilere yeterli eri\u015fim sa\u011flayam\u0131yorsa bu cihaz\u0131 uygunluk de\u011ferlendirmesinde e\u015fde\u011fer cihaz olarak kullanamaz. Kamuya a\u00e7\u0131k kaynaklardaki eksiklikler, yay\u0131n yanl\u0131l\u0131\u011f\u0131, g\u00fcncel olmayan bilgiler, bilinmeyen malzeme \u00f6zellikleri veya eri\u015filemeyen test raporlar\u0131 e\u015fde\u011ferlik karar\u0131nda a\u00e7\u0131k\u00e7a de\u011ferlendirilmelidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0130stisna \u015fartlar\u0131n\u0131n kar\u015f\u0131lanmas\u0131, mevcut klinik verilerin otomatik olarak yeterli oldu\u011fu anlam\u0131na gelmez. Klinik de\u011ferlendirme; cihaz\u0131n b\u00fct\u00fcn kullan\u0131m ama\u00e7lar\u0131n\u0131, endikasyonlar\u0131n\u0131, kontrendikasyonlar\u0131n\u0131, hedef gruplar\u0131n\u0131, klinik iddialar\u0131n\u0131, risklerini ve genel g\u00fcvenlilik ve performans gerekliliklerini kapsamal\u0131d\u0131r. Mevcut klinik kan\u0131tta kar\u015f\u0131lanmayan bir klinik soru bulunuyorsa ilave klinik veri \u00fcretilmesi gerekebilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Klinik ara\u015ft\u0131rman\u0131n zorunlu oldu\u011funa karar verilmesi h\u00e2linde MDR, her cihaz i\u00e7in sabit bir ara\u015ft\u0131rma say\u0131s\u0131 veya \u00f6rneklem b\u00fcy\u00fckl\u00fc\u011f\u00fc belirlemez. MDCG 2023-7\u2019ye g\u00f6re zorunlu klinik ara\u015ft\u0131rman\u0131n en az\u0131ndan cihaz\u0131n temel g\u00fcvenlilik ve performans iddialar\u0131n\u0131 destekleyecek pivotal nitelikte klinik veri \u00fcretmesi beklenir. Ara\u015ft\u0131rman\u0131n tasar\u0131m\u0131 cihaz\u0131n riskine, kullan\u0131m amac\u0131na ve mevcut kan\u0131t bo\u015fluklar\u0131na g\u00f6re olu\u015fturulmal\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Klinik ara\u015ft\u0131rma istisnas\u0131, \u201cklinik veri gerekmiyor\u201d anlam\u0131na gelmez. \u00dcretici her durumda yeterli klinik kan\u0131t olu\u015fturmal\u0131, klinik de\u011ferlendirme raporunu g\u00fcncel tutmal\u0131 ve PMS ile PMCF sonu\u00e7lar\u0131n\u0131 klinik de\u011ferlendirmeye geri beslemelidir. \u0130stisna yaln\u0131zca cihaz \u00fczerinde piyasaya arz \u00f6ncesinde klinik ara\u015ft\u0131rma yap\u0131lmas\u0131 zorunlulu\u011funa ili\u015fkindir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">S\u0131n\u0131f III olmayan ve implant edilebilir olmayan cihazlar MDCG 2023-7\u2019nin do\u011frudan kapsam\u0131 d\u0131\u015f\u0131ndad\u0131r. Bu cihazlarda klinik ara\u015ft\u0131rma ihtiyac\u0131; klinik de\u011ferlendirme hedefleri, mevcut klinik verilerin yeterlili\u011fi, cihaz\u0131n yenilik d\u00fczeyi, riskleri ve kan\u0131t bo\u015fluklar\u0131 \u00fczerinden belirlenir. Rehberin kapsam d\u0131\u015f\u0131nda olmas\u0131, bu cihazlarda hi\u00e7bir zaman klinik ara\u015ft\u0131rma gerekmeyece\u011fi anlam\u0131na gelmez.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">MDCG 2023-7\u2019deki yeni cihaz de\u011ferlendirmesi, MDR Madde 120 kapsam\u0131ndaki legacy cihazlarda \u201c\u00f6nemli de\u011fi\u015fiklik\u201d de\u011ferlendirmesiyle kar\u0131\u015ft\u0131r\u0131lmamal\u0131d\u0131r. Bir cihaz\u0131n yeni cihaz say\u0131lmas\u0131, ge\u00e7i\u015f h\u00fck\u00fcmlerinden yararlan\u0131p yararlanamayaca\u011f\u0131 veya tasar\u0131m de\u011fi\u015fikli\u011finin \u00f6nemli olup olmad\u0131\u011f\u0131 farkl\u0131 hukuki ve teknik de\u011ferlendirmelerdir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00dcreticinin teknik dosyas\u0131nda klinik ara\u015ft\u0131rma gereklili\u011fi i\u00e7in yaz\u0131l\u0131 bir karar kayd\u0131 bulunmal\u0131d\u0131r. Bu kay\u0131tta cihaz\u0131n implant edilebilir veya S\u0131n\u0131f III olup olmad\u0131\u011f\u0131, uygulanabilir istisna senaryosu, mevcut klinik verilerin yeterlili\u011fi, e\u015fde\u011ferlik sonucu, veri eri\u015fiminin seviyesi, onaylanm\u0131\u015f kurulu\u015f de\u011ferlendirmesi ve PMCF stratejisi birlikte g\u00f6sterilmelidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sonu\u00e7 olarak MDCG 2023-7, yeni implant edilebilir veya S\u0131n\u0131f III cihazlar\u0131n klinik ara\u015ft\u0131rmadan kolayl\u0131kla muaf tutulmas\u0131n\u0131 sa\u011flayan bir rehber de\u011fildir. Rehber; istisna yollar\u0131n\u0131, e\u015fde\u011ferlik ko\u015fullar\u0131n\u0131 ve veri eri\u015fimi beklentilerini daha a\u00e7\u0131k h\u00e2le getirir. \u015eartlar eksiksiz kar\u015f\u0131lanam\u0131yor veya mevcut klinik kan\u0131t cihaz\u0131n g\u00fcvenlilik ve performans\u0131n\u0131 yeterince desteklemiyorsa klinik ara\u015ft\u0131rma planlanmal\u0131d\u0131r.<\/p>","protected":false},"excerpt":{"rendered":"<p>Klinik de\u011ferlendirme yaln\u0131zca literat\u00fcr listesi de\u011fildir; cihaz\u0131n ama\u00e7lanan kullan\u0131m\u0131n\u0131, klinik iddialar\u0131n\u0131, risklerini ve performans kan\u0131tlar\u0131n\u0131 bir araya getiren s\u00fcrekli bir [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"kkqa_category":[455],"kkqa_letter":[467],"class_list":["post-13194","kkqa_question","type-kkqa_question","status-publish","hentry","kkqa_category-klinik-degerlendirme","kkqa_letter-c"],"_links":{"self":[{"href":"http:\/\/www.kalitekit.com.tr\/en\/wp-json\/wp\/v2\/kkqa_question\/13194","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.kalitekit.com.tr\/en\/wp-json\/wp\/v2\/kkqa_question"}],"about":[{"href":"http:\/\/www.kalitekit.com.tr\/en\/wp-json\/wp\/v2\/types\/kkqa_question"}],"author":[{"embeddable":true,"href":"http:\/\/www.kalitekit.com.tr\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.kalitekit.com.tr\/en\/wp-json\/wp\/v2\/comments?post=13194"}],"version-history":[{"count":0,"href":"http:\/\/www.kalitekit.com.tr\/en\/wp-json\/wp\/v2\/kkqa_question\/13194\/revisions"}],"wp:attachment":[{"href":"http:\/\/www.kalitekit.com.tr\/en\/wp-json\/wp\/v2\/media?parent=13194"}],"wp:term":[{"taxonomy":"kkqa_category","embeddable":true,"href":"http:\/\/www.kalitekit.com.tr\/en\/wp-json\/wp\/v2\/kkqa_category?post=13194"},{"taxonomy":"kkqa_letter","embeddable":true,"href":"http:\/\/www.kalitekit.com.tr\/en\/wp-json\/wp\/v2\/kkqa_letter?post=13194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}